Installers & builders · Australia

Installer / Builder
verification checklist

Has the platform supplier met their requirements? Tick each check before you install — from the design basis and paperwork through delivery, hold points and handover.

Information as at 23 October 2026General information — not engineering or legal advice.Designer side: Engineering Checklist →
Free account — save, share and collect evidence

Save a checklist per project, send your supplier a link to tick off what they've provided and attach files, then share the finished checklist with architects and superintendents for comment. Always free — includes a 30-day trial of the Mech Deck design tool.

Sign in free

Documents to expect in Queensland

Engineer registration
RPEQ (Professional Engineers Act 2002)
Design certificate (B1)
Form 15
Inspection certificate (F1)
Form 16
Final certificate (F3)
Form 21 Final inspection certificate
Falls guidance
Managing the risk of falls at workplaces Code of Practice
Site hazard note (A2, A4)
Cyclonic Region C in parts of the north

Example of a completed line: Result = Pass · Date = 12 Jan 2027 · Notes = “Certificate sighted, registration number checked on the register.” Items tagged Suggested are extra checks we recommend.

A

Before ordering — supplier's design basis

0/6
A2

Design is for THIS site, not a generic catalogue rating.

What a pass looks like: Engineering letter stating the site wind region, terrain category, importance level, roof pitch and building height, all inside the system's limits.
A3

Design loads match the plant actually being installed.

What a pass looks like: Load schedule showing imposed load plus the real equipment weights and support reactions; matches the mechanical equipment schedule.
A4

Cyclonic sites only (north Qld, northern WA, NT): cyclone design addressed.

What a pass looks like: Statement that debris impact and cyclic loading are covered, including screens and louvres.
A5

Designing engineer is qualified and registered where required in your state.

What a pass looks like: Registration / credential number on the documents (see state box); checked on the state register.
A6Suggested

Supplier holds current public liability and professional indemnity cover, and states the product warranty.

What a pass looks like: Certificates of currency sighted; written warranty covering structure, finish and fixings.
B

Supplier documents — sight before delivery or install

0/9
B1

Signed design certificate from the engineer.

What a pass looks like: Certificate named in the state box, signed and dated, referencing this project and the drawing revisions.
B2

Calculations and signed structural drawings; revision matches the approved building documents.

What a pass looks like: Drawing register shows the same revision as the certifier-approved set.
B3

Roof structure check: the metal roof frame can carry the platform loads.

What a pass looks like: Engineer's statement covering purlins, rafters and primary frame, with load path to primary structure (not roof sheeting alone).
B4

Fixing and connection details.

What a pass looks like: Fastener type, size and spacing; hold-down details; corrosion protection class; roof penetration and flashing details.
B5

Product compliance evidence for proprietary components.

What a pass looks like: Test reports or evidence of suitability (NCC Part A5); Queensland Form 73 if used; material grades and galvanising certificates.
B6

Access and edge-protection design to AS 1657:2018.

What a pass looks like: Guardrail, toe board, stair, ladder and gate details; edge protection.
B7

Installation instructions with engineer hold points.

What a pass looks like: Written fixing sequence, torque values, and a list of items the engineer must inspect before they are covered.
B8

Maintenance and inspection requirements.

What a pass looks like: Supplier maintenance advice and inspection intervals for the platform and its fixings.
B9Suggested

Rated load plate specified for the platform.

What a pass looks like: Drawing shows a durable sign stating the rated imposed load (e.g. 2.5 or 5.0 kPa) and maximum unit weight.
C

On delivery — before unloading and installing

0/5
C1

Components match shop drawings.

What a pass looks like: Part numbers, member sizes, material grade and finish checked against the approved shop drawings.
C2

No damage or defects.

What a pass looks like: No bent members, damaged galvanising or coating, cracked welds; items labelled and traceable.
C3

Fixings, flashings and isolation supplied as specified.

What a pass looks like: Quantities and types match the fixing schedule; no unapproved substitutions.
C4

Any substitution approved in writing by the engineer.

What a pass looks like: Signed engineer approval on file before the substituted item is used.
C5Suggested

Fasteners and metals are compatible with the roof sheeting and keep its warranty.

What a pass looks like: Roof sheeting manufacturer's compatibility guidance followed (no copper/lead/stainless contact or runoff onto COLORBOND® / ZINCALUME®).
D

Before install — site readiness

0/5
D1

Building approval in place and the platform is in the approved documents.

What a pass looks like: Approval / permit sighted; certifier aware of the engineer's inspection hold points.
D2

Roof frame as built matches the design.

What a pass looks like: Purlin spacing and rafter positions checked on site; any variation referred to the engineer before fixing.
D3

Roof work safety plan in place.

What a pass looks like: SWMS covering edge protection, fragile surfaces and rescue (Vic: OHS Regulations; WA: WHS (General) Regulations 2022).
D4

Final plant selection matches what the platform was designed for.

What a pass looks like: Equipment make, model, weight and footprint match the load schedule in A3.
D5Suggested

Lifting plan for materials and plant, with roof set-down limits.

What a pass looks like: Crane / hoist plan and a note of where bundles may be stacked without overloading purlins.
E

During install — hold points

0/6
E1

Engineer's hold-point inspections done before fixings or welds are concealed.

What a pass looks like: Inspection records or sign-off for each hold point listed in B7.
E2

Fasteners installed as designed.

What a pass looks like: Correct type, spacing and torque; dated photos kept.
E3

Roof penetrations flashed and sealed.

What a pass looks like: Flashings and sealing match the supplier / engineer detail; no roof sheeting left unsupported.
E4

Guardrails, stairs and ladders installed to AS 1657:2018.

What a pass looks like: Edge protection in place before the platform is used; gates and toe boards fitted.
E5

Dissimilar-metal isolation and coating touch-up done.

What a pass looks like: Isolation washers / gaskets fitted; cut or damaged coatings repaired per supplier.
E6Suggested

Deck level and roof drainage clear.

What a pass looks like: Deck checked level to tolerance; gutters, valleys and sheet ribs not blocked by supports or debris; swarf removed.
F

Completion and handover

0/7
F1

Engineer's inspection certificate for the as-built platform.

What a pass looks like: Certificate named in the state box, signed and dated, covering structure and fixings.
F2

As-built drawings and final calculations.

What a pass looks like: Drawings reflect any approved changes.
F3

Final building certificate issued.

What a pass looks like: Certificate named in the state box, issued by the certifier / authority.
F4

Operation and maintenance pack handed over.

What a pass looks like: Inspection intervals and a maintenance log started.
F5

Equipment commissioning and licensed-trade paperwork.

What a pass looks like: Electrical and refrigeration compliance documents from licensed trades.
F6

Defects closed out and sign-off recorded.

What a pass looks like: Punch list cleared; sign-off block completed.
F7Suggested

Load-rating and access signage fitted.

What a pass looks like: Rated load plate (B9) and 'authorised persons only' sign at the access point; photo in the handover pack.

Stop and escalate to the engineer / certifier if

  • — A certificate is unsigned, undated, for a different project, or the engineer cannot show required registration.
  • — The design does not state site-specific wind region and limits, or the site is outside the system's stated limits.
  • — Delivered parts, fixings or finishes differ from the drawings and there is no written engineer approval.
  • — The roof frame as built does not match the design, or fixings would go into sheeting only.
  • — Any hold point has been missed or fixings are already concealed.

Sign-off

The PDF includes signature lines for the installer and builder. Print it, sign and keep it with the handover pack.